There is an update available for your
Flow of Fluids 2009 Program.
This will update Flow of Fluids 2009 to the latest build
(revision A).
Eligibility for this update can be found in the
following manner:
Go to the Help menu in Flow of Fluids and choose About.
If the version says 11.01, no update is required.
If the Version does not say 11.01 click on the link
below to update your software.
Download the Update
Version number: 11.01
Items Resolved in the 2009 Flow of Fluids
Maintenance Release:
- An error with the new water table has been
discovered which affects the liquid density of
water at higher temperatures. Above 302 ºF (150
ºC) there is significant deviation between the
density calculated from the water table and
actual water density data from the International
Association for the Properties of Water and
Steam (IAPWS). A replacement table is installed
in the maintenance release which fixes this
problem. (PB#002_09)
- There was an issue with some 2005 systems
causing the program an unexpected exit once
opened in the 2009 version. The issue
involved pump definition and has been resolved.
- Some additional program stability issues
were identified and resolved. These
include XLink use with a certain combination of
Windows and Excel versions, some rare instances
of splitting pipes within PIPE-FLO, and when the
autoname feature exceeds the number of digits
specified in the autoname base. (PB#001-09)